DIAGNOSTIC TROUBLE CODE CHART
Air Conditioning System DTC No. | Detection Item | Memory | Link |
---|---|---|---|
B140287 | Lost Communication with Front Air Outlet Damper Control Servo Motor LIN Missing Message | Memorized |
|
B14037F | Front Air Outlet Damper Control Servo Motor Actuator Stuck Off | Memorized |
|
B141A11 | Room Temperature Sensor Circuit Short to Ground | Memorized |
|
B141A15 | Room Temperature Sensor Circuit Short to Battery or Open | Memorized |
|
B142A88 | Servo Motor LIN Communication Bus off | Memorized |
|
B143A87 | Lost Communication with Air Inlet Damper Control Servo Motor LIN Missing Message | Memorized |
|
B143B7F | Air Inlet Damper Control Servo Motor Actuator Stuck Off | Memorized |
|
B144B87 | Lost Communication with Front Left Air Mix Damper Control Servo Motor LIN Missing Message | Memorized |
|
B144C7F | Front Left Air Mix Damper Control Servo Motor Actuator Stuck Off | Memorized |
|
B145A87 | Lost Communication with Front Right Air Mix Damper Control Servo Motor LIN Missing Message | Memorized |
|
B145B7F | Front Right Air Mix Damper Control Servo Motor Actuator Stuck Off | Memorized |
|
B14B287 | Lost Communication with Front Panel LIN Missing Message | Memorized |
|
P007011 | Ambient Temperature Sensor Circuit Short to Ground | Memorized |
|
P007015 | Ambient Temperature Sensor Circuit Short to Battery or Open | Memorized |
|
P053011 | Refrigerant Pressure Sensor Circuit Short to Ground | Memorized |
|
P053015 | Refrigerant Pressure Sensor Circuit Short to Battery or Open | Memorized |
|
P05347A | Refrigerant Gas Fluid Leak or Seal Failure | Memorized |
|
P053511 | Evaporator Temperature Sensor Circuit Short to Ground | Memorized |
|
P053515 | Evaporator Temperature Sensor Circuit Short to Battery or Open | Memorized |
|
P06A014 | Compressor Solenoid Circuit Short to Ground or Open | Memorized |
|
U010087 | Lost Communication with ECM/PCM "A" Missing Message | Memorized |
|
U013187 | Lost Communication with Power Steering Control Module Missing Message | Memorized |
|
U014087 | Lost Communication with Body Control Module Missing Message | Memorized |
|
U015587 | Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message | Memorized |
|
U016387 | Lost Communication with Navigation Control Module Missing Message | Memorized |
|
To use the auxiliary key, press the knob and pull out the auxiliary key from the smart key.